Open Aur Needed Fir Attic Exhaust
The following product options will allow you to achieve an exhaust nfva of 528 square inches.
Open aur needed fir attic exhaust. This allows cool dry air to enter the attic at the lowest point helping to remove any warm moist air from inside the attic through the exhaust vents along the entire underside of the roof deck. In no case should the amount of exhaust ventilation exceed the amount of intake ventilation. Most building codes require a ratio of 1 150 ventilation space to attic floor space. Say the contractor is standing in front of a house that has an attic with 2 200 square feet.
Here s an example using the shortcut for the 1 150 code minimum. You can also contact your local municipality to check on building code in your area. 2 200 2 1 100 square inches of exhaust net free area needed. Always have a balanced ventilation system.
Dry air to enter the attic. Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca. Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space. Intake vents located at the lowest part of the roof under.
According to the home ventilating institute hvi powered attic ventilators need to move a minimum of 700 cubic feet per minute cfm for 1 000 sq. Select your preferred type of exhaust system. The uniform building code requires that the amount of venting area in the attic be equal to 1 150 of the area of the floor and in most circumstances it allows a ratio of 1. Cool air in hot air out attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator. Ft of attic space for example 20 x 50 to be effective.