Nyc Condensing Roof Vent Clearances
If not ok why and does anyone have any info on general guidelines for vent clearances on exterior ac condenser.
Nyc condensing roof vent clearances. Clothes dryer vent outlet. In no case should the curb be less than 14 inches in height. Clearance distances for the compressor condenser from water ice snow position so water snow or ice from roof or eaves cannot fall directly on unit. See figure 6 6.
152 4 mm above roof surface. Where the vent termination is located below an adjacent roof structure the termination point shall be located not less than 3 feet 914 mm from such structure. Any concerns with this install. Propane tank distance requirements.
Material should be placed between the built up roof membrane and the nailer. Where the metal chimney passes through a combustible roof it shall be guarded by a non combustible ventilating thimble of galvanized metal or equivalent non combustible material that extends at least nine inches below and above the roof construction. Mechanical work must comply with the nyc mechanical code which is part of the nyc construction codes but compliance with the building plumbing fuel gas and the nyc energy conservation code is also required. Btw i know the pictures aren t the greatest.
Lint clogging of the compressor condenser s condensing coils is likely to be a problem and the extra warm air won t help the cooling cycle efficiency or equipment life. Mechanical applicability of code and zoning. The dryer vent however was approx. Rooftop clearance distances for a c or heat pump compressor condenser units on rooftop applications locate unit at least 6 in.
Do not locate a compressor condenser unit where the clothes dryer vent will blow onto or close to the unit. In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents some high efficiency furnaces also include a plastic pipe for intake area and all types. Per the 2014 administrative code section 28 101 4 3 additions alterations renovations or repairs to. Vents shall terminate not less than 3 feet 914 mm above any forced air inlet located within 10 feet 3048 mm horizontally.
We prioritize maintaining highest quality products and providing excellent service to our end customers and our distributors. Water heater power vent vented directly behind ac condenser. One of the most visited subjects in the propane industry is distance requirements for propane tanks distance rules are applicable to propane tanks and their connections in relation to what surrounds them whether it s a house or another propane tank. Learn more about our company our products duravent offers over twenty different product lines for residential.
Traditional gas fired forced air furnaces produce hot combustion exhaust gasses and therefore need metal vent pipes or chimneys.