Osha s new ruling was designed in part to create more uniformity between the general industry and construction standards.
Osha fixed ladder roof hatch. For starters prior to the new ruling the only real guidance on fixed ladders came from the construction standards osha more 1926 1053 a 18 required the use of cages wells ladder safety devices or self retracting lifelines for fixed ladders of 24 feet or more. On fixed ladders the perpendicular distance from the centerline of the rungs to the nearest permanent object on the climbing side of the ladder shall be 36 inches for a pitch of 76 degrees and 30 inches for a pitch of 90 degrees fig. D 2 of this section with minimum clearances for intermediate pitches varying between these two limits in proportion to the slope except as provided in subparagraphs 3 and 5 of this paragraph. Personal fall arrest system or ladder safety system on fixed ladders and fixed ladders used on grain silos for emergency escape 10 18 2019.
Osha s general industry standard for fixed ladders is found in 29 cfr 1910 27. 1910 25 a application this section covers all stairways including standard spiral ship and alternating tread type stairs except for stairs serving floating roof tanks stairs on scaffolds stairs designed into machines or equipment and stairs on self propelled motorized equipment. The minimum perpendicular clearance between fixed ladder rungs cleats and steps and any obstruction behind the ladder shall be 7 inches 18 cm except in the case of an elevator pit ladder for which a minimum perpendicular clearance of 4 1 2 inches 11 cm is required. Note to paragraph d.
Grab bars not required at hatch exits. Per osha 1910 23 b 4 ladder rungs steps and cleats have a minimum clear width of 16 inches measured before installation of ladder safety systems for fixed ladders. As seen in the picture below featuring new ladder system we recommend a wider climbing surface to accommodate a ladder lifeline system and to make the ladder easier to climb. Leading usa manufacturer of architectural building products for over 75 years.
Figure d 2 slide step fixed ladder sections. Osha standard for roof openings roof hatch protection is addressed by osha standard 26 cfr 1910 23 entitled guarding floor and wall openings and holes full text of this standard is available online at www osha gov. We can fabricate any aluminum fixed access ship cage or custom ladder as well as platforms catwalks stairs walkways and more. 1910 23 open roof hatches should be protected.